ASTM F1869 PDF

Standard Test Method for Measuring Vapor Emission Rate (MVER) of Concrete Subfloor Using Anhydrous Calcium Chloride. Apparatus – the kit plus a gram. The applicable industry standard for this test, ASTM F, defined the scope of CaCl testing: “This test method covers the quantitative determination of the rate. Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Carbide.

Author: Digrel Faekus
Country: Sudan
Language: English (Spanish)
Genre: Automotive
Published (Last): 3 December 2011
Pages: 42
PDF File Size: 16.47 Mb
ePub File Size: 10.43 Mb
ISBN: 838-4-68133-673-6
Downloads: 53135
Price: Free* [*Free Regsitration Required]
Uploader: Kagasho

All floor coverings are susceptible to failure from excessive moisture vapor emissions. The moisture vapor emitted from a concrete slab is measured in pounds. Over decades, CaCl gained industry acceptance astj a practical standard.

The Workman’s History of Calcium Chloride Testing (F) – ASTM F Information

At that point, it was safe to install floor covering over a concrete substrate. CaCl tended to underestimate the true moisture conditions at the high end of the moisture spectrum, while it tended to overestimate the moisture conditions of older slabs. The aztm vapor emission rate only reflects the condition of the concrete floor at the time of the test. This led to continued moisture problems when that moisture eventually reached a covered concrete surface where they could no longer evaporate.

It is the responsibility of the user of this standard to establish appropriate safety and health practices, and determine the applicability of regulatory limitations prior to use.

Public Knowledge Base

Historical Version s – view previous versions v1869 standard. Builders, then, made threshold floor covering decisions based on errant readings. Although builders continue to use the CaCl moisture test, post-installation moisture problems eventually redefined it as a test method worthy of scrutiny. The CaCl moisture test is a building practice with lineage. Generally, high ambient RH slows concrete drying as the slab absorbs moisture vapor; low ambient RH causes concrete to emit moisture vapor.

  BARUTELLO ANALISI MATEMATICA PDF

G1869 to Active This link will always route to the current Active version of the standard.

The calcium chloride moisture test has been the industry standard for making this determination and is a practical, well-established and accepted test of dynamic moisture. All concrete subfloors emit some amount of moisture in vapor form. This site uses Akismet to reduce spam. But their truth has entered a new era and the challenges of moisture emissions-based testing are becoming increasingly clear.

Your email address will not be published.

Learn how your comment data is processed. The values given in ashm are mathematical conversions to SI units that are provided for information only and are not considered standard.

This is how concrete dries.

ASTM F1869

The CaCl moisture test produced data based on moisture vapor emission rate MVERthe quantitative indication of how many pounds of slab aetm evaporated from square feet of concrete over a hour period. Where the challenge became clear was in determining whether the surface emission rate determined by desiccant weight gain truly reflected the moisture conditions deeper in the slab. Concrete moisture emission is a natural process driven by environmental conditions.

Referenced Documents purchase separately The documents listed below are referenced within axtm subject standard but are not provided as part of the standard. The results obtained reflect the condition of the concrete floor surface at the time of testing and may not indicate future conditions.

  CARSON MCCULLERS THE BALLAD OF THE SAD CAFE PDF

Therefore, the natural migration process of concrete moisture drying is influenced by environment. In fact, moisture-plagued concrete slabs certified by ASTM F protocol proved to be a patterned and persistent challenge to the concrete flooring industry — so much so that industry professionals began to investigate the scientific integrity of the CaCl moisture test. Work Item s – proposed revisions of this standard. In light of such research, the American Society for Testing and Materials made two changes to moisture measurement industry standards.

CaCl measured only the top one-half to three-quarters inch of the slab. This measurement is the equivalent weight of water evaporating from ft 2 of concrete surface in a 24—h period.

Home to ASTM F1869

It will produce quantified results directly applicable to flooring manufacturer’s specifications. Submit a Comment Cancel reply Your email address will not be published. Concrete moisture vapor migrates from the bottom of concrete slabs to their surfaces in order to evaporate.

Concrete floor installers began using the calcium chloride CaCl moisture test back in asttm early s to conclude when a new concrete slab was fit for floor coverings.